Top Air (TA 1200/1600, 80/90 Boom) Installation Manual TA01

Seite 2

74.4 List of Parts Item Part Number Name QuantityB05 44706-01 KIT CABLE TIE BLACK 10 PCS 21 IN 150 PCS 7.5 IN 1B11 44743 MOUNTING BRACKET MAIN L

Seite 3 - Contents

84.5 Hydraulic Fitting Kit Details (P/N: 44865-31) Item Part Number Name QuantityPictureF02 103839 TEE ADAPTER - 6FJXR 6MJT 4F03 104634 CAP - 6F

Seite 4 - 1 Introduction

94.6 Alternate Cabling Some Top Air sprayers may require different cabling depending on the connectors used near the valve block. Please refer to

Seite 5 - 2 Technical Specifications

105 Pre-Install Checklist The pre-install checklist is necessary to check the existing sprayer functionality before the installation. 1. Unfold

Seite 6 - 3 General UC5 System Layout

116 Ultrasonic Sensor Installation 6.1 Ultrasonic Sensor Serial Number Arrangement When installing the UC5 sensors, start with the smallest seri

Seite 7 - 4 Kit Parts

126.2 Ultrasonic Sensor Mounting Guidelines The following guidelines will ensure optimal sensor performance and prevent sensor measurement error.

Seite 8

136.3 Low Profile Bracket Mounting Guidelines 1. Minimize the distance between the bolts to prevent bending the bracket and prevent the bracket

Seite 9

146.4 Wing Sensor Installation 1. The sensor bracket should be oriented forward (ahead of the boom). 2. Typically the best mounting location fo

Seite 10 - 4.4 List of Parts

156.5 Rainflap Installation Rainflaps are only installed in the wing sensor brackets. 1. Insert one side of the rainflap rod into the pre-bent

Seite 11 - 6 M B - 6 M OR X 90

166.6 Main Lift Sensor Installation Figure 13: Main Lift Bracket Assembly 1. There are a variety of ways to mount the main lift bracket on mos

Seite 12 - 4.6 Alternate Cabling

Printed in Canada Copyright  2009 by NORAC Systems International Inc. Reorder P/N: UC5-BC-TA01-INST Rev K (Top Air - TA 1200/1600, 80/90 Boom) NOTIC

Seite 13 - 5 Pre-Install Checklist

177 Roll Sensor Installation 7.1 Bracket Assembly 1. Securely mount the roll sensors to the included roll sensor brackets using the #6 machine

Seite 14

187.2 Roll Sensor Mounting Guidelines: Center Pivot Booms 1. When mounting the roll sensors, mount one to the boom frame and one to the chassis

Seite 15

197.3 Roll Sensor Mounting on a Top Air Sprayer Figure 19: Roll Sensor Mounting

Seite 16

208 Module Installation An optional module mounting bracket kit is available for purchase from NORAC. The mounting brackets are compatible with

Seite 17

218.2 Valve Module 1. Install the valve module (E02) to the top of the NORAC valve block. Orient the 6-pin Deutsch (CANbus) connectors towards

Seite 18 - 6.5 Rainflap Installation

22 Figure 23: Valve Module Bracket Installation 5. Connect the valve module CANbus to cable C01 from the control module. Route cable C02 from

Seite 19

238.3 Input Module 1. Install the input module (E03) on the boom near the sprayer valve block. Secure it to the boom using cable ties or option

Seite 20 - 7 Roll Sensor Installation

249 Connecting the Sensors to the CANbus 1. Fasten the 8-way coupler (E11) to the boom with cable ties. Route cable C03 from the input module t

Seite 21

2510 Hydraulic Installation Ensure all pressure has been bled from the system before disconnecting any lines or fittings. Hydraulic pressure wi

Seite 22

2610.2 Valve Block Mounting 1. Mount the valve block on the center section of the boom near the sprayer valve block, as illustrated in Figure 28

Seite 23 - 8 Module Installation

Contents 1 Introduction ... 12

Seite 24 - 8.2 Valve Module

2710.3 Hydraulic Plumbing – All Models From this point on in the installation the booms will be inoperative until the hydraulics are fully insta

Seite 25

2811 Software Setup 1. Start up the sprayer and test the sprayer’s functionality. The display terminal does not need to be powered on for the o

Seite 26 - 8.3 Input Module

2912 Cable Drawings 12.1 ITEM C01: 43220-10 - CABLE UC5 NETWORK 14 AWG - 10M 12.2 ITEM C02: 43220-01 - CABLE UC5 NETWORK 14 AWG - 1M

Seite 27

3012.3 ITEM C03: 43220-03 - CABLE UC5 NETWORK 14 AWG - 3M 12.4 ITEM C05: 43210-20 - CABLE UC5 NETWORK 18 AWG - 20M

Seite 28 - 10 Hydraulic Installation

3112.5 ITEM C10: 43230-04 – CABLE UC5 VALVE DT TO DT

Seite 29 - 10.2 Valve Block Mounting

3212.6 ITEM C20: 43240-01 – CABLE UC5 INTERFACE TILT DT

Seite 30

3312.7 ITEM C21: 43240-07 – CABLE UC5 INTERFACE MAIN DT (WITH AUX 1 & 2)

Seite 31 - 11 Software Setup

3412.8 ITEM C30: 43250-06 – CABLE UC5 BATTERY PIGTAIL FUSED

Seite 32 - 12 Cable Drawings

Canada NORAC Systems International Inc. Phone: (+1) 306 664 6711 Toll Free: 1 800 667 3921 Shipping Address: 3702 Kinnear Place Saskatoon, SK S7P

Seite 33

11 Introduction Congratulations on your purchase of the NORAC UC5 Spray Height Control System. This system is manufactured with top quality comp

Seite 34

22 Technical Specifications CAN ICES-3(A)/NMB-3(A) This device complies with part 15 of the FCC Rules. Operation is subject t

Seite 35

33 General UC5 System Layout Figure 1 illustrates the general layout of the UC5 system components: Figure 1: General UC5 System Layout

Seite 36 - (WITH AUX 1 & 2)

44 Kit Parts 4.1 Kit Overview Figure 2: TA01 System Parts

Seite 37

54.2 Hydraulic Plumbing – Model Year 2012 and Newer Figure 3: TA01 Hydraulic Plumbing Model Year 2012 and Newer

Seite 38

64.3 Hydraulic Plumbing – Model Year 2011 and Older Figure 4: TA01 Hydraulic Plumbing Model Year 2011 and Older