Hagie (STS 12 2000-2004) Installation Manual HG01
74.4 Hydraulic Fitting Kit Details (P/N: 44865-14) Item Part Number Name QuantityPictureF01 103195 6MJT 2F02 104584 MALE TO FEMALE ADAPTER - 6MB
85 Pre-Install Checklist The pre-install checklist is necessary to check the existing sprayer functionality before the installation. 1. Unfold
96 Ultrasonic Sensor Installation 6.1 Bracket Assembly Assemble the breakaway sensor bracket as illustrated in Figure 5, following the instructi
106.2 Ultrasonic Sensor Serial Number Arrangement When installing the UC5 sensors, start with the smallest serial number on the left-hand side, a
116.3 Ultrasonic Sensor Mounting Guidelines The following guidelines will ensure optimal sensor performance and prevent sensor measurement error.
126.4 Wing Sensor Installation 1. The sensor bracket should be oriented forward (ahead of the boom). 2. Typically the best mounting location fo
136.5 Main Lift Sensor Installation Figure 9: Main Lift Bracket Assembly 1. There are a variety of ways to mount the main lift bracket on most
147 Roll Sensor Installation 7.1 Bracket Assembly 1. Securely mount the roll sensors to the included roll sensor brackets using the #6 machine
157.2 Roll Sensor Mounting Guidelines: Front Mounted Rigid Booms 1. When mounting the roll sensors, mount one to the boom and one to the chassis
167.3 Boom-Frame Roll Sensor Mounting 1. Install the roll sensor with the lowest serial number onto the top part of the center boom section on
Printed in Canada Copyright 2008 by NORAC Systems International Inc. Reorder P/N: UC5-BC-HG01-INST Rev K (STS 12 2000-2004) NOTICE: NORAC Systems
177.4 Chassis Roll Sensor Mounting 1. Mount the chassis roll sensor on the main sprayer chassis, with the cable facing the right hand wing. 2.
188 Hydraulic Installation Ensure all pressure has been bled from the system before disconnecting any lines or fittings. Hydraulic pressure wil
198.2 Valve Block Mounting 1. Install the valve block (V01) onto the plate mounted beside the Hagie valve block. Figure 17: Valve Block Mountin
208.3 Hydraulic Plumbing From this point on in the installation the booms will be inoperative until the hydraulics are fully installed. 1. Afte
219 Module Installation An optional module mounting bracket kit is available for purchase from NORAC. The mounting brackets are compatible with
229.2 Input Module 1. Install the input module (E03) on the boom near the sprayer valve block. Secure it to the boom using cable ties or option
239.3 Valve Module 1. Install the valve module (E02) to the top of the NORAC valve block. Orient the 6-pin Deutsch (CANbus) connectors towards
24 Figure 22: Valve Module Bracket Installation 5. Connect the valve module CANbus to cable C01 from the chassis roll sensor. Route cable C03
2510 Connecting the Sensors to the CANbus 1. Fasten the 8-way coupler to the boom with cable ties. 2. Connect the boom frame roll sensor (E04)
2611 Software Setup 1. Start up the sprayer and test the sprayer’s functionality. The display terminal does not need to be powered on for the
Contents 1 Introduction ... 12
2712 Cable Drawings 12.1 ITEM C01: 43220-05 - CABLE UC5 NETWORK 14 AWG 5M 12.2 ITEM C03: 43220-03 - CABLE UC5 NETWORK 14 AWG - 3M
2812.3 ITEM C05: 43220-01 - CABLE UC5 NETWORK 14 AWG - 1M 12.4 ITEM C06: 43210-20 - CABLE UC5 NETWORK 18 AWG - 20M
2912.5 ITEM C10: 43230-04 – CABLE UC5 VALVE 2PIN DT TO 2PIN DT
3012.6 ITEM C20: 43240-01 – CABLE UC5 INTERFACE TILT DT
3112.7 ITEM C21: 43240-07 – CABLE UC5 INTERFACE MAIN DT (WITH AUX 1&2)
3212.8 ITEM C30: 43250-06 – CABLE UC5 BATTERY PIGTAIL FUSED
Canada NORAC Systems International Inc. Phone: (+1) 306 664 6711 Toll Free: 1 800 667 3921 Shipping Address: 3702 Kinnear Place Saskatoon, SK S7P
11 Introduction Congratulations on your purchase of the NORAC UC5 Spray Height Control System. This system is manufactured with top quality comp
22 Technical Specifications CAN ICES-3(A)/NMB-3(A) This device complies with part 15 of the FCC Rules. Operation is subject t
33 General UC5 System Layout Figure 1 illustrates the general layout of the UC5 system components: Figure 1: General UC5 System Layout
44 Kit Parts 4.1 Kit Overview Figure 2: HG01 System Parts
54.2 Hydraulic Plumbing Figure 3: HG01 Hydraulic Plumbing Parts NOTE: Hoses are supplied by Hagie Do not use high speed power tools/drills wh
64.3 List of Parts Item Part Number Name QuantityB10 44728 MOUNTING BRACKET COMPLETE UC4 BREAKAWAY EXTENDED 2B11 44743 MOUNTING BRACKET MAIN LIFT
Kommentare zu diesen Handbüchern