Norac UC5-BC-WK01 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Gartengeräte Norac UC5-BC-WK01 herunter. NORAC UC5-BC-WK01 User Manual [de] [fr] [it] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Installation Manual

Walker Installation Manual WK01

Seite 2

74.4 Hydraulic Fitting Kit Details (P/N: 44865-73) Item Part Number Name Quantity PictureF01 104369 PLUG - 6MBP 2F02 103312 MALE ADAPTER - 6MB 6M

Seite 3 - Contents

85 Pre-Install Checklist The pre-install checklist is necessary to check the existing sprayer functionality before the installation. 1. Unfold

Seite 4 - 1 Introduction

96 Ultrasonic Sensor Installation 6.1 Ultrasonic Sensor Serial Number Arrangement When installing the UC5 sensors, start with the smallest seria

Seite 5 - 2 Technical Specifications

106.2 Ultrasonic Sensor Mounting Guidelines The following guidelines will ensure optimal sensor performance and prevent sensor measurement error.

Seite 6 - 3 General UC5 System Layout

116.3 Low Profile Bracket Mounting Guidelines 1. Minimize the distance between the bolts to prevent bending the bracket and prevent the bracket

Seite 7 - 4 Kit Parts

126.4 Wing Sensor Installation 1. The wing sensor mounting brackets (B20) are the two brackets with the shorter mounting flange. 2. The sensor

Seite 8 - 4.2 Hydraulic Plumbing

136.5 Rainflap Installation Rainflaps are only installed in the wing sensor brackets. 1. Insert one side of the rainflap rod into the pre-bent

Seite 9 - 4.3 List of Parts

146.6 Main Lift Sensor Installation 1. The main lift mounting bracket (B21) is the bracket with the longer mounting flange. 2. There are a var

Seite 10 - 6 M B - 6 M OR X 90

157 Roll Sensor Installation 7.1 Bracket Assembly 1. Securely mount the roll sensors to the included roll sensor brackets using the #6 machine

Seite 11 - 5 Pre-Install Checklist

167.2 Roll Sensor Mounting Guidelines: Front Mounted Rigid Booms 1. When mounting the roll sensors, mount the lowest serial number onto the boom

Seite 12

Printed in Canada Copyright  2014 by NORAC Systems International Inc. Reorder P/N: UC5-BC-WK01-INST Rev A (Walker) NOTICE: NORAC Systems Internati

Seite 13

177.3 Roll Sensor Mounting Figure 18: Roll Sensor Mounting Boom Frame Roll Sensor Chassis Roll Sensor

Seite 14

188 Module Installation An optional module mounting bracket kit is available for purchase from NORAC. The mounting brackets are compatible with

Seite 15

19 Figure 20: Power Connection Figure 21: Cabling Access through Floor Hatch

Seite 16 - 6.5 Rainflap Installation

208.2 Input Module 1. Install the input module (E03) near the Walker valve block and secure it using cable ties. 2. Connect the free end of t

Seite 17

218. Connect a second cable C02 to the 3-way coupler (E10) and route towards the valve module. Figure 23: Input Module Connections Figure 24:

Seite 18 - 7 Roll Sensor Installation

228.3 Valve Module 1. Install the valve module (E02) to the top of the NORAC valve block. Orient the 6-pin Deutsch (CANbus) connectors towards

Seite 19

23 Figure 27: Valve Module Bracket Installation 5. Connect cable C02 to the valve module CANbus from the 3-way coupler (E10). Route cable C03

Seite 20 - 7.3 Roll Sensor Mounting

249 Connecting the Sensors to the CANbus 1. Connect the chassis roll sensor to the 3-way coupler (E10). 2. Fasten the 8-way coupler (E11) to

Seite 21 - 8 Module Installation

2510 Hydraulic Installation Ensure all pressure has been bled from the system before disconnecting any lines or fittings. Hydraulic pressure wi

Seite 22 - Figure 20: Power Connection

2610.2 Valve Block Mounting 1. Mount the valve block using the mounting bracket (B01) as shown in Figure 30 and Figure 31. Figure 30: Valve

Seite 23 - 8.2 Input Module

Contents 1 Introduction ... 12

Seite 24

2710.3 Hydraulic Plumbing From this point on in the installation the booms will be inoperative until the hydraulics are fully installed. 1. Aft

Seite 25 - 8.3 Valve Module

2811. At the accumulator, remove the existing fitting from between the hoses and accumulator (Figure 33). Insert the 6FJXL 6MJT tee (F09) in its

Seite 26

2911 Software Setup 1. Start up the sprayer and test the sprayer’s functionality. The display terminal does not need to be powered on for the o

Seite 27

3012 Cable Drawings 12.1 ITEM C01: 43220-07 - CABLE UC5 NETWORK 14 AWG – 7M 12.2 ITEM C02: 43220-03 - CABLE UC5 NETWORK 14 AWG - 3M

Seite 28 - 10 Hydraulic Installation

3112.3 ITEM C03: 43220-0.5 - CABLE UC5 NETWORK 14 AWG – 0.5M 12.4 ITEM C05: 43210-20 - CABLE UC5 NETWORK 18 AWG - 20M

Seite 29 - 10.2 Valve Block Mounting

3212.5 ITEM C10: 43230-04 – CABLE UC5 VALVE DT TO DT

Seite 30 - 10.3 Hydraulic Plumbing

3312.6 ITEM C20: 43240-01 – CABLE UC5 INTERFACE TILT DT

Seite 31

3412.7 ITEM C21: 43240-07 – CABLE UC5 INTERFACE MAIN DT (WITH AUX 1 & 2)

Seite 32 - 11 Software Setup

3512.8 ITEM C30: 43250-04 – CABLE UC5 BATTERY AMP FUSED

Seite 33 - 12 Cable Drawings

Canada NORAC Systems International Inc. Phone: (+1) 306 664 6711 Toll Free: 1 800 667 3921 Shipping Address: 3702 Kinnear Place Saskatoon, SK S7P

Seite 34

11 Introduction Congratulations on your purchase of the NORAC UC5 Spray Height Control System. This system is manufactured with top quality comp

Seite 35

22 Technical Specifications CAN ICES-3(A)/NMB-3(A) This device complies with part 15 of the FCC Rules. Operation is subject t

Seite 36

33 General UC5 System Layout Figure 1 illustrates the general layout of the UC5 system components: Figure 1: General UC5 System Layout Do n

Seite 37 - (WITH AUX 1 & 2)

44 Kit Parts 4.1 Kit Overview Figure 2: WK01 System Parts

Seite 38

54.2 Hydraulic Plumbing Figure 3: WK01 Hydraulic Plumbing

Seite 39

64.3 List of Parts Item Part Number Name QuantityB01 44700-07 MOUNTING BRACKET VALVE NITRO 4000 SERIES BC KIT 1B05 44706-01 KIT CABLE TIE BLACK 1

Kommentare zu diesen Handbüchern