Case IH (4420, 3320) Installation Manual CS03
74.4 Hydraulic Fitting Kit Details (P/N: 44865-06) Item Part Number Name Quantity PictureF02 103312 MALE ADAPTER - 6MB 6MJ 2F03 104586 TEE ADAPT
85 Pre-Install Checklist The pre-install checklist is necessary to check the existing sprayer functionality before the installation. 1. Unfold
96 Ultrasonic Sensor Installation 6.1 Ultrasonic Sensor Serial Number Arrangement When installing the UC5 sensors, start with the smallest seria
106.2 Ultrasonic Sensor Mounting Guidelines The following guidelines will ensure optimal sensor performance and prevent sensor measurement error.
116.3 Low Profile Bracket Mounting Guidelines 1. Minimize the distance between the bolts to prevent bending the bracket and prevent the bracket
126.4 Wing Sensor Installation 1. The wing sensor mounting brackets (B20) are the two brackets with the shorter mounting flange. 2. The sensor
136.5 Rainflap Installation Rainflaps are only installed in the wing sensor brackets and are not installed for 120’ booms. 1. Insert one side o
146.6 Main Lift Sensor Installation 1. The main lift mounting bracket (B21) is the bracket with the longer mounting flange. 2. There are a var
157 Roll Sensor Installation 7.1 Bracket Assembly 1. Securely mount the roll sensors to the included roll sensor brackets using the #6 machine
167.2 Roll Sensor Mounting Guidelines: Trapeze-Suspended Booms 1. When mounting the roll sensors, mount one to the trapeze link (boom frame) and
Printed in Canada Copyright 2009 by NORAC Systems International Inc. Reorder P/N: UC5-BC-CS03-INST Rev L (Case IH 4420, 3320) NOTICE: NORAC System
177.3 Roll Sensor Mounting on a Case Sprayer Figure 17: Roll Sensor Mounting (Viewed from the rear of sprayer)
188 Module Installation An optional module mounting bracket kit is available for purchase from NORAC. The mounting brackets are compatible with
198.2 Valve Module 1. Install the valve module (E02) to the top of the NORAC valve block. Orient the 6-pin Deutsch (CANbus) connectors towards
20 Figure 21: Valve Module Bracket Installation 5. Connect the valve module CANbus to cable C01 from the control module. Route cable C02 from
218.3 Input Module 1. Install the input module (E03) on the boom near the sprayer valve block. Secure it to the boom using cable ties or option
229 Connecting the Sensors to the CANbus 1. Route cable C03 from the input module to the 8-way coupler (E11). 2. Connect both roll sensors to t
2310 Hydraulic Installation Ensure all pressure has been bled from the system before disconnecting any lines or fittings. Hydraulic pressure wi
2410.2 Valve Block Mounting 1. A suitable mounting location for the valve block is illustrated in Figure 26. 2. Insert the threaded rod into th
2510.3 Hydraulic Plumbing From this point on in the installation the booms will be inoperative until the hydraulics are fully installed. The fa
2611 Software Setup 1. Start up the sprayer and test the sprayer’s functionality. The display terminal does not need to be powered on for the
Contents 1 Introduction ... 12
2712 Cable Drawings 12.1 ITEM C01: 43220-10 - CABLE UC5 NETWORK 14 AWG - 10M 12.2 ITEM C02: 43220-01 - CABLE UC5 NETWORK 14 AWG - 1M
2812.3 ITEM C03: 43220-03 - CABLE UC5 NETWORK 14 AWG - 3M 12.4 ITEM C05: 43210-20 - CABLE UC5 NETWORK 18 AWG - 20M
2912.5 ITEM C10: 43230-04 – CABLE UC5 VALVE DT TO DT
3012.6 ITEM C20: 43240-01 – CABLE UC5 INTERFACE TILT DT
3112.7 ITEM C21: 43240-22 – CABLE UC5 INTERFACE MAIN DT (240”)
3212.8 ITEM C30: 43250-04 – CABLE UC5 BATTERY AMP FUSED
Canada NORAC Systems International Inc. Phone: (+1) 306 664 6711 Toll Free: 1 800 667 3921 Shipping Address: 3702 Kinnear Place Saskatoon, SK S7P
11 Introduction Congratulations on your purchase of the NORAC UC5 Spray Height Control System. This system is manufactured with top quality comp
22 Technical Specifications CAN ICES-3(A)/NMB-3(A) This device complies with part 15 of the FCC Rules. Operation is subject t
33 General UC5 System Layout Figure 1 illustrates the general layout of the UC5 system components: Figure 1: General UC5 System Layout Do n
44 Kit Parts 4.1 Kit Overview Figure 2: CS03 System Parts
54.2 Hydraulic Plumbing Figure 3: CS03 Hydraulic Plumbing
64.3 List of Parts Item Part Number Name QuantityB05 44706-01 KIT CABLE TIE BLACK 10 PCS 21 IN 150 PCS 7.5 IN 1B17 44972 SENSOR MOUNTING BRACKET