Redball 690 (2006+) Installation Manual Spray Height Control System Improving the competitiveness of Industry and Agriculture through Precisi
74 INSTALLATION PROCEDURE 4.1 EXISTING SYSTEM CHECK It is necessary to check the existing system’s functionality before installing the UC4+ Spray
8Table 4: Boom Test Record (WITHOUT UC4+ Spray Height Control system) Working RPM: Boom Trial #1 [Sec] Trial #2 [Sec] Trial #3 [Sec] Avg Time [Sec]
94.3 WING SENSOR INSTALLATION 1. Assemble the Breakaway Sensor Mounting Brackets (B11) as show in Figure 4 and Figure 5. Figure 4: Breakaway Sens
10 When installing the UC4+ sensors (E02), start with the smallest serial number on the left hand side proceeding to the largest serial number on t
11Apply a light coating of the supplied Permatex Anti-seize grease to all threaded parts upon installation. Figure 9: Sensor Serial Number Instal
124.4 MAIN LIFT SENSOR INSTALLATION 1. Assemble the main lift sensor bracket (B11) as shown in Figure 10. Figure 10: Main Lift Sensor Bracket 2.
134.5 ROLL SENSOR INSTALLATION Mount the roll sensors (E03 and E04) to the included roll sensor brackets using the machine screws and nylon lock nu
144.5.1 Boom Frame Roll Sensor Mounting 1. Use the supplied hardware to mount the boom frame roll sensor (E04) as shown in Figure 15. When mount
154.5.2 Chassis Roll Sensor Mounting 1. It is often best to cable tie the chassis roll sensor in place. When mounting the chassis roll sensor fol
164.6 HYDRAULIC INSTALLATION WARNING! The hydraulic system creates very high pressure. Before disconnecting any hydraulic lines ensure all press
Printed in Canada Copyright 2005-08 by NORAC Systems International Inc. Reorder P/N: UC4+BC+RB1-INST Rev F (Redball 690) NOTICE NORAC Systems Inter
174.6.2 Valve Mounting 1. Mount the NORAC valve (V01) on the sprayer using the valve mounting bracket (B10). 2. As shown in Figure 20, screw shor
184.7 ELECTRICAL INSTALLATION 1. Install the UC4+ Control Panel (E01) in the cab of the sprayer. Mount the panel where it will be clearly visible
19 Ensure the UC4 Control Panel’s power is OFF for the remaining installation (Bottom of switch pressed IN). Use caution when handling the +12 V po
20 Figure 24: Valve Cable Connections 13. Connect the CAN Node cable (C02B) to the 4-pin AMP plug on C11 (Figure 25). 14. Route the CAN Node cable (
214.8 COMPLETING THE INSTALLATION 1. Start up your sprayer and test the sprayer’s functionality. The NORAC Control Panel does not need to be powe
225 ELECTRICAL REFERENCE – CABLE DRAWINGS 5.1 ITEM C02: 44668 – CABLE SENSOR BRANCH
235.2 ITEM C02B: 44664 – CABLE UC4 CAN NODE DUAL 5FT
245.3 ITEM C03: 44656D – CABLE VALVE VARIABLE RATE DT
255.4 ITEM C10: 44650-35 – CABLE POWER GENERIC PULL-TYPE L = 240" (6.10m)
265.5 ITEM C11: 44651-03 – EXTENSION CABLE VALVE GENERIC 365” (9.27m)
TABLE OF CONTENTS 1 INTRODUCTION ...
275.6 ITEM C12: 44658-22 – CABLE UC4 INTERFACE RB1 MAIN
285.7 ITEM C13: 44658-23 – CABLE UC4 INTERFACE RB1 WINGS
Canada NORAC Systems International Inc. CALL TOLL FREE: 1-800-667-3921 (306)664-6711 SHIPPING ADDRESS: 3702 Kinnear Place Saskatoon, SK S7P 0A6
11 INTRODUCTION Congratulations on your purchase of the NORAC UC4+ Spray Height Control System. This system is manufactured with top quality comp
22 GENERAL SYSTEM DESCRIPTION Figure 1 depicts the general system layout of the UC4+ Spray Height Control System. Figure 1: System Components an
33 PARTS LISTS The parts that come with your UC4+ Spray Height Control System are listed in Table 1. The item number on the left side of this ta
4Table 2: 44865-24 - Hydraulics Fittings Kit Details Item Part Number Name QuantityPictureF01 44928 ORIFICE INSERT .047 IN ONE WAY 2F02 103312 MALE
5The parts that come with your UC4+ Spray Height Control System are shown below in their general installation configuration. Figure 2: UC4+ Spray H
6 Figure 3: Hydraulic Components