Rogator 854, 1054 & 1254 Series Installation Manual RG4
7Item Part Number Name QuantityPictureF13 104628 MALE TO FEMALE ADAPTER - 12FJ 8MJ 1F14 104386 MALE TO FEMALE ADAPTER - 8FJ 6MJ 1 6 M B - 6 M OR X
83.6 Alternate Cabling Some Rogator sprayers may require different cabling depending on the connectors used near the valve block. Please refer to
94 Pre-Install Checklist The pre-install checklist is necessary to check the existing sprayer functionality before the installation. 1. Unfold
105 Ultrasonic Sensor Installation 5.1 Bracket Assembly Assemble the breakaway sensor bracket as illustrated in Figure 5, following the instruct
115.2 Ultrasonic Sensor Serial Number Arrangement When installing the sensors, start with the smallest serial number on the left-hand side, and p
125.3 Ultrasonic Sensor Mounting Guidelines The following guidelines will ensure optimal sensor performance and prevent sensor measurement error.
135.4 Wing Sensor Installation 1. The sensor bracket should be oriented forward (ahead of the boom). 2. Typically the best mounting location f
146 Roll Sensor Installation 6.1 Bracket Assembly 1. Securely mount the roll sensors to the included roll sensor brackets using the #6 machine
156.2 Roll Sensor Mounting Guidelines: Center Pivot Booms 1. When mounting the roll sensors, mount the roll sensor without the temperature probe
166.3 Temperature Probe Once the block is mounted, fasten the temperature probe from E03 to the NORAC valve block using the included 3/8x1/2” bol
Printed in Canada Copyright 2012 by NORAC Systems International Inc. Reorder P/N: UC4.5-BC-RG4-INST Rev E (Rogator 854, 1054 & 1254 Series) NOT
177 Electrical Installation 1. Install the UC4.5 Control Panel (E01) in the cab of the sprayer. Mount the panel where it will be clearly visibl
185. In the electrical panel towards the front of the sprayer, wire the white wire on C30 to +12V and the black wire to Ground. Refer to Figure
19 Figure 17: Access Panel and Plates Figure 18: Cable Configurations: C03, C12, C13 and C11 6. Run cable C11 to the rear of the sprayer, in the
2010. Unplug the existing connectors on the Rogator left and right boom control valve connections. There are four connectors to unplug: SV9 (RIGHT
2113. Connect the valve interface cable (C03) to connector S6 on the valve extension cable (C11). 14. Connect the 2-pin connectors on the valve
228 Hydraulic Installation Ensure all pressure has been bled from the system before disconnecting any lines or fittings. Hydraulic pressure wil
238.2 Valve Block Mounting Ensure that no hydraulic components will interfere with any sprayer parts or be pulled tight at any time. 1. A suita
248.3 Hydraulic Plumbing From this point on in the installation the booms will be inoperative until the hydraulics are fully installed. 1. Afte
256. Install F12 between the tank port and the existing tank line (Figure 25). 7. Tee H05 in to the open port on F12 using F13 (Figure 25). 8.
269 Software Setup 1. Start up the sprayer and test the sprayer’s functionality. The NORAC control panel does not need to be powered on for th
Contents 1 Introduction ... 12
2710 Cable Drawings 10.1 ITEM C03: 44656D – CABLE VALVE VARIABLE RATE DT
2810.2 ITEM C05: 43210-20 - CABLE UC5 NETWORK 18 AWG - 20M 10.3 ITEM C08: 43220-03 - CABLE UC5 NETWORK 14 AWG - 3M
2910.4 ITEM C10: 44650-50 - CABLE UC4.5 POWER GENERIC SELF-PROPELLED
3010.5 ITEM C11: 44651-50 - CABLE UC4.5 EXTENSION VALVE GENERIC
3110.6 ITEM C12: 44658-32 – CABLE UC4 INTERFACE ROGATOR 854, 1054, 1254
3210.7 ITEM C13: 44658-33 – CABLE UC4 INTERFACE MP2 GND2 BYPASS 10.8 ITEM C30: 43250-04 – CABLE UC5 BATTERY AMP FUSED
Canada NORAC Systems International Inc. Phone: (+1) 306 664 6711 Toll Free: 1 800 667 3921 Shipping Address: 3702 Kinnear Place Saskatoon, SK S7P
11 Introduction Congratulations on your purchase of the NORAC UC4.5 Spray Height Control System. This system is manufactured with top quality co
22 General UC4.5 System Layout Figure 1 illustrates the general layout of the UC4.5 system components: Figure 1: General UC4.5 System Layout
33 Kit Parts 3.1 Kit Overview Figure 2: RG4 System Parts
43.2 Hydraulic Plumbing Figure 3: RG4 Hydraulic Plumbing
53.3 List of Parts Item Part Number Name QuantityB05 44706-01 KIT CABLE TIE BLACK 10 PCS 21 IN 150 PCS 7.5 IN 1B10 44728 MOUNTING BRACKET COMPLE
63.4 Hydraulic Fitting Kit Details (P/N: 44865-26) Item Part Number Name QuantityPictureF01 44928 ORIFICE INSERT .047 IN ONE WAY 2F02 103312 MALE
Kommentare zu diesen Handbüchern